Batts and blankets can leave gaps and voids.
Adding fiberglass batts to attic blown in insulation.
The material tends to compress over time.
You d need a thickness of.
Because blown in insulation which is fiberglass generally can go on top of the existing insulation the negative thing about blown in insulation is that it makes the attic absolutely impassable when you re done and you need a lot more thickness of it because it has more air inside of it than you would if you used fiberglass bats.
To keep the blown in insulation from falling through the attic hatch opening make a 2x12 dam around the hatch perimeter.
Once installed and expanded to the uniform manufactured thickness batts offer a known r factor.
Cut fiberglass batts by scoring them with a utility knife.
The photo above shows an attic insulated with blown cellulose.
Place the batts into.
Batt or rolled insulation or blown loose fill insulation fiberglass or cellulose can be installed on top of old insulation.
When blown into attics and wall spaces loose fill fiberglass offers an average r 2 5 thermal value per inch the higher the number the greater the insulating effect.
Install fiberglass batts over existing batt insulation.
Insulation should be rolled out perpendicular to the joists and unfaced rolls should be used.
Fiberglass comes from what i ve heard one major fiberglass insulation manufacturer call a rapidly renewable resource sand.
Size each piece to fit snugly between the floor joists in your attic.
I don t know about that but it s a common insulation material that works much better in the blown form than in batts.
The r factor of blown in fiberglass is usually 2 3 to 2 8 per inch of material.
Insulate your attic with fiberglass batts when it comes to insulating your attic there are really only two types of insulation worth considering fiberglass batts or blown in insulation.
Cut two layers of r 19 fiberglass batt insulation slightly larger than the hatch and staple duct tape to the hatch edges to secure it in place.
Blown in insulation thickness can vary in an attic space.
Working with fiberglass insulation requires wearing personal protection gear.
To install fiberglass batts over existing insulation lay the batts perpendicular to the joists so they do not compress the insulation below whether you live in a warm weather state as i do or in a cooler northern climate it s hard to stay comfortable and keep your energy bills in check if you don t have adequate insulation in the attic.
Batts don t fit well in odd spaces.
This will lead to non uniform r values.
Put on goggles and gloves to protect yourself while handling fiberglass insulation.
Blown in insulation consists of bags of fiberglass or cellulose that are chopped up and blown in to the attic or wall from a machine.