Door hardware mounting heights 2010 ada changes.
Ada door hardware height.
Door handles pulls latches locks and other operating devices shall be installed 34 inches 864 mm minimum and 48 inches 1219 mm maximum above the finished floor.
Thresholds at doorways shall not exceed 3 4 in 19 mm in height for exterior sliding doors or 1 2 in 13 mm for other types of doors.
Hardware required for accessible door passage shall be mounted no higher than 48 in 1220 mm above finished floor.
Minimum number at least 60 of public entrances must be accessible in new construction in addition to entrances directly serving tenancies parking facilities pedestrian tunnels and elevated walkways.
This guide explains scoping and technical requirements for accessible entrances doors and gates in the ada standards.
All of the requirements discussed can be found in the lengthy section 404 of the americans with disabilities act.
Door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
Handles pulls panic bars.
Operable parts shall be operable with one hand and shall not require tight grasping pinching or twisting of the wrist.
In the previous edition of the ada standard section 4 13 9 included this statement.
Ada door handle requirements height of hardware etc door opening and closing requirements.